DocumentCode :
2794492
Title :
Estimation of void volume in insulation system from partial discharge parallelogram measurements
Author :
Peiyu, Ren ; Ge, Jiang ; Zhiming, Liu
Author_Institution :
Dept. of Electr. Eng., Xi´´an Jiaotong Univ., China
fYear :
1991
fDate :
8-12 Jul 1991
Firstpage :
684
Abstract :
A practical means of obtaining the geometrical capacitance increment between the solid insulation capacitance (with cavities short-circuited completely) and the low-voltage capacitance without discharges in an insulation system from parallelogram measurements has been used to estimate the fractional volume of voids in the insulation system. This method has been evaluated by tests on models and generator insulation. From a comparison between calculated results and those obtained from experiment, it is found that more accurate estimation can be made by using this geometrical capacitance increment. An attempt is made to estimate the void volume of HV generator stator insulation
Keywords :
capacitance measurement; insulation testing; machine insulation; machine testing; partial discharges; volume measurement; HV generator stator insulation; fractional volume of voids; generator insulation; geometrical capacitance increment; insulation system; low-voltage capacitance; partial discharge parallelogram measurements; solid insulation capacitance; tests on models; void volume estimation; Capacitance measurement; Circuits; Dielectrics and electrical insulation; Electric variables measurement; Equations; Partial discharge measurement; Partial discharges; Solids; Voltage; Volume measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Properties and Applications of Dielectric Materials, 1991., Proceedings of the 3rd International Conference on
Conference_Location :
Tokyo
Print_ISBN :
0-87942-568-7
Type :
conf
DOI :
10.1109/ICPADM.1991.172157
Filename :
172157
Link To Document :
بازگشت