• DocumentCode
    2794597
  • Title

    A non-intrusive winding heating method for induction motor using soft-starter for preventing moisture condensation

  • Author

    Zhang, Pinjia ; Du, Yi ; Habetler, Thomas G. ; Bin Lu

  • Author_Institution
    GE Global Res. Center, Electr. Machines Lab., Niskayuna, NY, USA
  • fYear
    2010
  • fDate
    12-16 Sept. 2010
  • Firstpage
    1306
  • Lastpage
    1311
  • Abstract
    Moisture condensation may cause degradation of key motor components when a motor is de-energized. To prevent moisture condensation, a motor´s temperature must be maintained higher than the ambient temperature when de-energized. This paper proposes a non-intrusive motor heating technique using soft-starters. By controlling the operation of the solid-state switches in soft-starters, adjustable ac current can be injected into the three phases of the stator windings without inducing any output torque. The motor temperature can therefore be maintained at a desired temperature due to the heat dissipation during current injection. In addition, two motor temperature control approaches are proposed in this paper to minimize the required energy consumption for preventing moisture condensation. The proposed technique is experimentally validated on a 7.5-hp ODP (open drip proof) induction motor. The experimental results show that the average stator winding temperature can reaches 9° above the ambient temperature with acceptable current magnitudes. In addition, it is shown that the motor temperature rise can be controlled by adjusting the operation of the solid-state switches in soft-starters. The importance of the proposed technique lies in its non-invasive nature: the technique only uses the existing hardware of soft-starters; the motor´s condition is not interrupted since no output torque is induced during the current injection. The proposed winding heating technique can be easily extended to other types of ac machines or inverter-fed applications.
  • Keywords
    condensation; induction motors; machine control; machine windings; temperature control; AC machines; adjustable AC current; ambient temperature; average stator winding temperature; heat dissipation; induction motor; inverter-fed machines; moisture condensation prevention; motor temperature control approach; nonintrusive winding heating method; open drip proof; power 7.5 hp; soft-starter; solid-state switches; Heating; Induction motors; Moisture; Stator windings; Temperature measurement; AC machine; ac machine protection; induction machine; moisture condensation; soft-starter; solid-state motor starter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    978-1-4244-5286-6
  • Electronic_ISBN
    978-1-4244-5287-3
  • Type

    conf

  • DOI
    10.1109/ECCE.2010.5617811
  • Filename
    5617811