DocumentCode :
2798070
Title :
Coordinated active and reactive power management implementation based on dual-stage PLL method for grid-connected PV system with battery
Author :
Liu, Liming ; Zhou, Yan ; Li, Hui
Author_Institution :
Center for Adv. Power Syst., Florida State Univ., Tallahassee, FL, USA
fYear :
2010
fDate :
12-16 Sept. 2010
Firstpage :
328
Lastpage :
335
Abstract :
This paper presents a single phase grid-connected PV system integrating energy storage system (ESS) using cascaded multilevel inverter. A Discrete Fourier Transform (DFT) Phase Locked Loop (PLL) method is proposed to improve system dynamic performance. A coordinated active and reactive power management (ARPM) strategy is developed based on the dual-stage DFT PLL method. The point of common coupling (PCC) overvoltage caused by reverse power flow can be mitigated by properly storing extra solar energy in the local ESS. In particular, the proposed system can provide wide range reactive power compensation to improve power quality and system stability. Furthermore, a control system, including dual-current-loop control, energy storage voltage balance control and ARPM control, is developed in grid-connected mode. Finally, a 3.5 kW single phase grid-connected PV system with batteries is implemented in the laboratory. Both simulation and experimental results are presented to verify the validity of the proposed power management strategy.
Keywords :
cascade systems; control system synthesis; discrete Fourier transforms; electric current control; energy storage; invertors; load flow; overvoltage; phase locked loops; photovoltaic power systems; power grids; power supply quality; power system stability; reactive power; secondary cells; solar power; voltage control; ESS; battery; cascaded multilevel inverter; coordinated active power management; discrete Fourier transform; dual-current-loop control; dual-stage DFT PLL method; energy storage system; energy storage voltage balance control; grid-connected PV system; phase locked loop method; point of common coupling overvoltage; power quality; power system stability; reactive power compensation; reactive power management; reverse power flow; solar energy; Discrete Fourier transforms; Harmonic analysis; Inverters; Phase locked loops; Reactive power; Resource management; Switches; PV system; cascaded multilevel inverter; energy storage system; phase locked loop; power management;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
Conference_Location :
Atlanta, GA
Print_ISBN :
978-1-4244-5286-6
Electronic_ISBN :
978-1-4244-5287-3
Type :
conf
DOI :
10.1109/ECCE.2010.5618018
Filename :
5618018
Link To Document :
بازگشت