• DocumentCode
    2798247
  • Title

    Digital type power-failure detector with wide AC frequency response

  • Author

    Harada, Ikko ; Ueno, Fumio ; Inoue, Takahiro ; Oota, Ichirou

  • Author_Institution
    Kumamoto Univ., Japan
  • fYear
    1991
  • fDate
    5-8 Nov 1991
  • Firstpage
    238
  • Lastpage
    243
  • Abstract
    A proposed quick detector possesses the period data as a digital counter value, and has the novel feature that, when an AC power failure lasts more than one cycle, a power failure signal is generated. The following advantages also exist: this detector can detect a power failure about 100 ms faster than a conventional detector, which checks power failures by means of DC voltage drop for a 60 Hz power source; it operates on a wide AC frequency range, and therefore operates on AC frequencies including not only commercial power but also a high-frequency subdistribution system in buildings, vessels and aircraft; an auxiliary pulse synchronous to the AC power source before it fails is generated during the power failure; the detector is constructed without analog devices such as an operational amplifier and is realized in an IC form
  • Keywords
    detectors; digital instrumentation; fault location; power measurement; power supplies to apparatus; AC power failure; DC voltage drop; IC; digital power-failure detector; power failure signal; wide AC frequency response; AC generators; Aircraft; Buildings; Counting circuits; Detectors; Frequency response; Power generation; Pulse amplifiers; Signal generators; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Energy Conference, 1991. INTELEC '91., 13th International
  • Conference_Location
    Kyoto
  • Print_ISBN
    0-87942-670-5
  • Type

    conf

  • DOI
    10.1109/INTLEC.1991.172403
  • Filename
    172403