Title :
Development of a totally enclosed fan cooled traction motor
Author :
Noda, Shinichi ; Mizuno, Sueyoshi ; Koyama, Taihei ; Shiraishi, Shigetomo
Author_Institution :
Toshiba Corp., Fuchu, Japan
Abstract :
The intake of dust and dirt-contained outside air into the motor while driving causes the maintenance of dismantling and clean-up operation once every three years. Besides, excessive acoustic noise during high speed operation is produced by the cooling fan on the rotor. Totally enclosed, airtight motor was developed not only to deal with the dust intake problem and thereby eliminate the requirement of periodical dismantling and clean-up operation, but also to reduce acoustic noise. Excessive noise of internal cooling fan was decreased by newly developed uneven pitch blade fan. Further, traction motor without external fan was developed thermo-fluid simulation. These motor were tested.
Keywords :
acoustic noise; dust; fans; traction motors; acoustic noise; airtight motor; clean-up operation; dust intake problem; fan cooled traction motor; internal cooling fan; periodical dismantling; rotor; thermo-fluid simulation; uneven pitch blade fan; Acoustic noise; Blades; Cooling; Frequency modulation; Induction motors; Noise; Traction motors; Induction motor; acoustic noise uneven pitch fan; thermo-fluid simulation; totally enclosed fan cooled traction motor;
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
Conference_Location :
Atlanta, GA
Print_ISBN :
978-1-4244-5286-6
Electronic_ISBN :
978-1-4244-5287-3
DOI :
10.1109/ECCE.2010.5618030