• DocumentCode
    2798315
  • Title

    Development of a totally enclosed fan cooled traction motor

  • Author

    Noda, Shinichi ; Mizuno, Sueyoshi ; Koyama, Taihei ; Shiraishi, Shigetomo

  • Author_Institution
    Toshiba Corp., Fuchu, Japan
  • fYear
    2010
  • fDate
    12-16 Sept. 2010
  • Firstpage
    272
  • Lastpage
    277
  • Abstract
    The intake of dust and dirt-contained outside air into the motor while driving causes the maintenance of dismantling and clean-up operation once every three years. Besides, excessive acoustic noise during high speed operation is produced by the cooling fan on the rotor. Totally enclosed, airtight motor was developed not only to deal with the dust intake problem and thereby eliminate the requirement of periodical dismantling and clean-up operation, but also to reduce acoustic noise. Excessive noise of internal cooling fan was decreased by newly developed uneven pitch blade fan. Further, traction motor without external fan was developed thermo-fluid simulation. These motor were tested.
  • Keywords
    acoustic noise; dust; fans; traction motors; acoustic noise; airtight motor; clean-up operation; dust intake problem; fan cooled traction motor; internal cooling fan; periodical dismantling; rotor; thermo-fluid simulation; uneven pitch blade fan; Acoustic noise; Blades; Cooling; Frequency modulation; Induction motors; Noise; Traction motors; Induction motor; acoustic noise uneven pitch fan; thermo-fluid simulation; totally enclosed fan cooled traction motor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    978-1-4244-5286-6
  • Electronic_ISBN
    978-1-4244-5287-3
  • Type

    conf

  • DOI
    10.1109/ECCE.2010.5618030
  • Filename
    5618030