Condition monitoring of a power station
Author :
Yu, X.Z. ; Birlasekaran, S. ; Choi, S.S. ; Yong, Y.C. ; Lim, T.F.
Author_Institution :
Sch. of Electr. & Electron. Eng., Nanyang Technol. Inst., Singapore
Volume :
2
fYear :
2000
fDate :
2000
Firstpage :
1029
Abstract :
The aim of this study is to obtain a signature of the aging level of the various power apparatus in a generating station, with the view to initiate a condition-based maintenance (CBM) program. On-site off-line condition monitoring was carried out on a section of the station consisting of a 300 MVA, 16 kV 3φ generator 7, a 300 MVA, 16/230 kV oil-filled step-up generator transformer T/F 7, a 20 MVA, 16/6.6 kV unit service transformer, a 2.17 MVA, 16/0.6 kV exciter transformer, about 100 m of a 3φ, 230 kV underground pressurized oil-filled cable and a 3φ, 230 kV SF6 gas insulated switchgear (GIS) system. The study is focused on recovery voltage measurement (RVM), polarisation current measurement (PCM) and frequency response analysis (FRA). From the test measurements and analysis, it is shown that for composite insulation such as that used in transformers, the extended Debye model describes well the conditions of the insulation. For solid insulation used in a generator, the universal fractional law appears to be more suitable. Furthermore, from FRA measurements carried out on two transformers, it is shown that a fault on the HV winding of one of the transformers was identified
Keywords :
AC generators; condition monitoring; electric current measurement; frequency response; gas insulated switchgear; insulation testing; maintenance engineering; power cables; power stations; power transformers; transformer windings; underground cables; voltage measurement; 0.6 kV; 100 m; 16 kV; 2.17 MVA; 20 MVA; 230 kV; 300 MVA; 6.6 kV; HV winding fault; SF6; SF6 gas insulated switchgear; aging level; composite insulation; condition monitoring; condition-based maintenance program; exciter transformer; extended Debye model; frequency response analysis; oil-filled step-up generator transformer; on-site off-line condition monitoring; polarisation current measurement; power station; recovery voltage measurement; underground pressurized oil-filled cable; unit service transformer; universal fractional law; Aging; Condition monitoring; Distributed power generation; Gas insulation; Oil filled cables; Oil insulation; Power generation; Power transformer insulation; Switchgear; US Department of Transportation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power System Technology, 2000. Proceedings. PowerCon 2000. International Conference on
Conference_Location :
Perth, WA
Print_ISBN :
0-7803-6338-8
Type :
conf
DOI :
10.1109/ICPST.2000.897162
Filename :
897162
Link To Document :
بازگشت