Abstract
The ground penetrating radar (GPR) are widely used in recent years due to its potential applications and unique capabilities, especially in the earthquake search or rescue. In this paper, a novel adaptive line enhancer (ALE) algorithm for human respiration monitoring through obstacle with low-power GPR is presented. The results of through wall experiments show that it is feasible to use this algorithm to monitor the respiration of human target through the obstacle. The correlation of the human target´s breathing rate between the simultaneously measured results obtained by our method and by the contact respiratory chest band using Biopac mpl50 measurement system is very good.
Keywords
earthquakes; ground penetrating radar; pneumodynamics; Biopac mpl50 measurement system; GPR; adaptive line enhancer algorithm; contact respiratory chest band; earthquake search and rescue; ground penetrating radar; human respiration monitoring; human target breathing rate; through wall experiment; through wall human respiration monioring; Correlation; Ground penetrating radar; Humans; Monitoring; Noise; Signal processing algorithms; adaptive line enhancer (ALE); ground penetrating radar(GPR); respiration monitor; ultra-wideband(UWB);
fLanguage
English
Publisher
ieee
Conference_Titel
Ground Penetrating Radar (GPR), 2012 14th International Conference on
Conference_Location
Shanghai
Print_ISBN
978-1-4673-2662-9
Type
conf
DOI
10.1109/ICGPR.2012.6254999
Filename
6254999
Link To Document