Effects of truncation of transmission projections on cardiac SPECT images acquired by a right-angle dual-camera with half-fan-beam collimators
Author :
Beekman, Freek J. ; Kamphuis, Chris
Author_Institution :
Dept. of Nucl. Med., Utrecht Univ., Netherlands
Volume :
2
fYear :
1997
fDate :
9-15 Nov 1997
Firstpage :
1264
Abstract :
Right-angle dual-head SPECT systems equipped with half-fan-beam collimators have some advantages right-angle dual-head systems with parallel-hole collimators. A potential drawback of the half-fan-beam system in cardiac studies is that it potentially truncates the transmission data and therefore yields attenuation maps containing inaccuracies in an area to the dorso-lateral region of the torso. The objective of this study is to investigate whether the transmission projection truncation introduces artifacts into iteratively reconstructed emission images of the heart. To this end, a combined cardiac emission transmission study was simulated, modeling 514 mm wide detectors and collimators with focal line distances of 890 mm. Emission images were reconstructed iteratively on the basis of truncated and untruncated attenuation maps. The iterative reconstruction methods enable to include the detector response, and compensate for attenuation and scatter in media with non-uniform density. The results indicate that attenuation- and scatter-corrected cardiac studies are not significantly influenced by the truncation of dorso-lateral region of the patient in the transmission projections, even if the patient is extremely large
Keywords :
biomedical equipment; cameras; cardiology; image reconstruction; medical image processing; single photon emission computed tomography; 514 mm; 890 mm; attenuation maps; cardiac SPECT images; emission images; half-fan-beam collimators; iterative reconstruction; medical diagnostic imaging; medical instrumentation; nonuniform density media; nuclear medicine; parallel-hole collimators; right-angle dual-camera; torso dorso-lateral region; transmission projections truncation effects; Attenuation; Collimators; Detectors; Electromagnetic scattering; Hospitals; Image reconstruction; Nuclear medicine; Particle scattering; Shape; Single photon emission computed tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1997. IEEE
Conference_Location :
Albuquerque, NM
ISSN :
1082-3654
Print_ISBN :
0-7803-4258-5
Type :
conf
DOI :
10.1109/NSSMIC.1997.670540
Filename :
670540
Link To Document :
بازگشت