• DocumentCode
    2812168
  • Title

    Autopsy report on three SLAC X-Band Klystron output circuits

  • Author

    Laurent, L. ; Jongewaard, E.

  • Author_Institution
    SLAC Nat. Accel. Lab., Menlo Park, CA, USA
  • fYear
    2009
  • fDate
    28-30 April 2009
  • Firstpage
    542
  • Lastpage
    543
  • Abstract
    Three different SLAC designed and fabricated X-Band (11.424 GHz) Klystrons, including both solenoid and PPM focused, have reached end of life status and the output circuits have been cross sectioned and SEM analyzed. This paper will provide a brief overview of the SLAC X-Band Klystron development program and discuss the autopsy results on the output circuits for the three klystrons, all of which have operated at peak power levels exceeding 50 MW.
  • Keywords
    klystrons; scanning electron microscopy; Klystron development program; PPM; SEM analysis; SLAC X-Band Klystron output circuits; autopsy report; solenoid; Autopsy; Circuits; Electric breakdown; Heating; Iris; Klystrons; Laboratories; Radio frequency; Solenoids; Waveguide discontinuities; Pulse Heating; RF Breakdown; X-Band Klystron; XL-PPM; XL4; XP1;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Vacuum Electronics Conference, 2009. IVEC '09. IEEE International
  • Conference_Location
    Rome
  • Print_ISBN
    978-1-4244-3500-5
  • Electronic_ISBN
    978-1-4244-3501-2
  • Type

    conf

  • DOI
    10.1109/IVELEC.2009.5193449
  • Filename
    5193449