• DocumentCode
    2812859
  • Title

    Analysis on vibration and vibration-elimination of nuclear-powered pipe

  • Author

    Fu, Xiangqian ; Wang, Chao ; Yu, Si ; Yin, Hui ; Zhang, Dawei ; Liu, Meng ; Chen, Cong

  • Author_Institution
    Sch. of Power & Mech. Eng., Wuhan Univ., Wuhan, China
  • fYear
    2011
  • fDate
    15-17 July 2011
  • Firstpage
    4762
  • Lastpage
    4765
  • Abstract
    Some pipe lines of a nuclear power plant exists serious vibration that seriously affected the normal production safety. By the spectral analysis of measured time domain signal, the main vibration frequency of the pipe lines was obtained. The model analysis was processed with pipe stress analysis software CAESAR II. The natural frequency was found. According to the causes of pipe lines vibration, the simple way of eliminating the vibration was given, and the results showed that the vibrating method effect is effective.
  • Keywords
    nuclear power stations; pipes; stress analysis; vibrations; natural frequency; nuclear power plant; nuclear-powered pipe; pipe stress analysis software CAESAR II; pipelines vibration; production safety; spectral analysis; time domain signal; vibration frequency; vibration-elimination; Analytical models; Fluids; Mechanical engineering; Pipelines; Pumps; Vibrations; model analysis; natural frequency; pipe vibration; vibration elimination;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on
  • Conference_Location
    Hohhot
  • Print_ISBN
    978-1-4244-9436-1
  • Type

    conf

  • DOI
    10.1109/MACE.2011.5988076
  • Filename
    5988076