• DocumentCode
    2816749
  • Title

    Analysis on the worst load angle of Z-shaped concrete columns

  • Author

    Wang, Tiecheng ; Chen, Xuan

  • Author_Institution
    Sch. of Civil Eng., Tianjin Univ., Tianjin, China
  • fYear
    2011
  • fDate
    15-17 July 2011
  • Firstpage
    5602
  • Lastpage
    5605
  • Abstract
    The worst load angle of Z-shaped section reinforced concrete column is calculated at double bias voltage in the method of numerical analysis. The variation of the worst load angle according to different material characteristics and section is analyzed. It is shown that, material characteristics of concrete, reinforcing steel etc. almost has no effect on the worst load angle of Z-type section column, while the variation of section aspect ratio and the ratio of height to thickness has an obvious effect on the worst load angle. In the paper, the equations of correlations is regressed according to calculated results.
  • Keywords
    construction components; numerical analysis; regression analysis; reinforced concrete; Z-shaped section reinforced concrete column; height-thickness ratio; numerical analysis; section aspect ratio; worst load angle; Civil engineering; Concrete; Educational institutions; Equations; Mathematical model; Numerical analysis; Z-shaped section reinforced concrete column; numerical analysis; section aspect ratio; the ratio of height to thickness; the worst load angle;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on
  • Conference_Location
    Hohhot
  • Print_ISBN
    978-1-4244-9436-1
  • Type

    conf

  • DOI
    10.1109/MACE.2011.5988296
  • Filename
    5988296