DocumentCode
2819434
Title
Screening for obstructive sleep apnoea based on the electrocardiogram-the computers in cardiology challenge
Author
Raymond, B. ; Cayton, Rm ; Bates, Ra ; Chappell, Mj
fYear
2000
fDate
2000
Firstpage
267
Lastpage
270
Abstract
The authors present a method of screening for obstructive sleep apnoea based on the electrocardiogram (ECG). The algorithm combines information from the ECG-derived respiration (EDR) signal and the RR interval tachogram. Power spectral features from the EDR signal were computed using the discrete harmonic wavelet transform, considering the power at the respiratory frequency and at frequencies below 0.1 Hz. Cycles of tachy/bradycardia (consistent with an arousal from sleep, as would be expected at the end of an episode of apnoea) were identified front the RR interval tachogram. Features were collated into minute-by-minute vectors and passed to a classifier. The algorithm correctly classified 81% of all minutes in the test database, with 29/30 patients correctly identified as apnoea or normal. Visual classification produced 92% correct classification, with all 30 patients correct
Keywords
discrete wavelet transforms; electrocardiography; feature extraction; medical signal processing; sleep; spectral analysis; vectors; 0.1 Hz; ECG-derived respiration signal; RR interval tachogram; computers in cardiology challenge; discrete harmonic wavelet transform; electrodiagnostics; minute-by-minute vectors; obstructive sleep apnoea screening; power spectral features; tachy/bradycardia cycles; test database; visual classification; Cardiology; Discrete wavelet transforms; Electrocardiography; Frequency; Heart; Hospitals; Physiology; Power engineering and energy; Sleep apnea; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Computers in Cardiology 2000
Conference_Location
Cambridge, MA
ISSN
0276-6547
Print_ISBN
0-7803-6557-7
Type
conf
DOI
10.1109/CIC.2000.898508
Filename
898508
Link To Document