Title :
Validating expert system rule confidences using data mining of myocardial perfusion SPECT databases
Author :
Cooke, Cd ; Santana, Ca ; Morris, Ti ; DeBraal, L. ; Ordonez, C. ; Omiecinski, E. ; Ezquerra, Nf ; Garcia, Ev
Author_Institution :
Emory Univ., Atlanta, GA, USA
Abstract :
The authors´ goal with this study was to use data mining techniques, applied to imaging and textual patient databases, to validate the confidences (certainty factors) of the heuristic rules in the authors´ previously described Expert System, PERFEXTM. A relational database combining textual and imaging information was generated from 655 patients who had undergone both stress/rest myocardial perfusion SPECT and coronary angiography. Initial data mining was concentrated on heuristic rules involving myocardial perfusion defects and the LAD vascular territory. The results show the robustness of the expert system, and furthermore show that data mining of large databases combining textual and imaging information can be used to validate and potentially improve the confidence levels associated with heuristic rules in expert systems
Keywords :
data mining; haemorheology; medical expert systems; muscle; relational databases; single photon emission computed tomography; visual databases; certainty factors; coronary angiography; expert system rule confidences validation; heuristic rules; medical diagnostic imaging; myocardial perfusion SPECT databases data mining; nuclear medicine; textual patient databases; Angiography; Association rules; Data mining; Expert systems; Image databases; Itemsets; Myocardium; Noise measurement; Relational databases; Robustness;
Conference_Titel :
Computers in Cardiology 2000
Conference_Location :
Cambridge, MA
Print_ISBN :
0-7803-6557-7
DOI :
10.1109/CIC.2000.898642