DocumentCode
2822703
Title
Simulation of prestressed concrete channel quality test by different electric heating method
Author
Jiang, Yinjun ; Zhu, Yonghua
Author_Institution
Sch. of Civil Eng., Wuhan Univ., Wuhan, China
fYear
2011
fDate
15-17 July 2011
Firstpage
6819
Lastpage
6822
Abstract
Due to lack of effective detection method, channel quality accidents of post-tensioned concrete construction cannot be discovered on time. An infrared detection principle based on electric heating is intended to be put forward to solve the above mentioned problem. Two main electrify methods, continuously or intermittently, are discussed. The results of the numeric simulation on the temperature field of a prestressed concrete component indicate that the electric heating infrared detection technology, for its energy consumption, efficiency and safety, is feasible for detecting the channel quality of prestressed concrete component, but the electrify method, continuously or intermittently, needs to be designed to avoid high thermal stress which will damage the strand and the concrete.
Keywords
concrete; electric heating; mechanical testing; quality management; channel quality accident; detection method; electric heating infrared detection technology; electric heating method; electrify method; energy consumption; high thermal stress; infrared detection principle; numeric simulation; post-tensioned concrete construction; prestressed concrete channel quality test; prestressed concrete component; temperature field; Concrete; Infrared heating; Resistance heating; Steel; Stress; electric heating; prestressed concrete component; temperature field simulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on
Conference_Location
Hohhot
Print_ISBN
978-1-4244-9436-1
Type
conf
DOI
10.1109/MACE.2011.5988613
Filename
5988613
Link To Document