• DocumentCode
    2823411
  • Title

    Test of post-fire bearing capacity of the circular steel tube with different coating

  • Author

    Yin, Jie ; Wang, Xintang

  • Author_Institution
    Dept. of Civil Eng., Ningbo Univ., Ningbo, China
  • fYear
    2011
  • fDate
    15-17 July 2011
  • Firstpage
    6947
  • Lastpage
    6950
  • Abstract
    In order to look into the post-fire bearing capacity of the steel tabular columns protected with different materials, the fire test was conducted for a set of circular steel tubes protected with different materials such as gypsum fireproof panel, bamboo plywood and the ordinary lumber core plywood, and the steel tube without any protective material. The axial compressive bearing capacity of the specimens after exposure to fire are tested and analyzed. The test results show that the post-fire bearing capacity of the steel tubes protected with different materials varies evidently, and the maximum value of response temperature has the greatest effect. Finally comparison of the test result and the result given with existing rule is made, and the computational formula of post-fire bearing capacity of the steel tabular short column is put forward by imitation.
  • Keywords
    compressive strength; compressive testing; fires; flameproofing; pipes; protective coatings; steel; axial compressive bearing capacity; bamboo plywood; circular steel tabular columns; coating; gypsum fireproof panel; lumber core plywood; post-fire bearing capacity; protective material; response temperature; Civil engineering; Coatings; Electron tubes; Fires; Materials; Resistance; Steel; fireproof materials; post-fire bearing capacity; steel tabular tubes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on
  • Conference_Location
    Hohhot
  • Print_ISBN
    978-1-4244-9436-1
  • Type

    conf

  • DOI
    10.1109/MACE.2011.5988646
  • Filename
    5988646