DocumentCode :
2823418
Title :
Stress characterization of electroplated gold layers for low temperature surface micromachining
Author :
Margesin, B. ; Bagolini, A. ; Guarnieri, Valerio ; Giacomozzi, Flavio ; Faes, A. ; Pal, R. ; Decarli, M.
Author_Institution :
ITC-irst, Povo, Italy
fYear :
2003
fDate :
5-7 May 2003
Firstpage :
402
Lastpage :
405
Abstract :
In this work, the stress of electroplated gold films has been analyzed versus plating current density and bath temperature. Two different plating solutions have been adopted, one being based on cyanide-gold salt, the other on sulfite-gold. Gold surface quality was investigated in the experimented range of plating temperature and current density, in order to control the limit conditions for plating: surface roughness and non-uniformity appear whenever deposition parameters are brought to the limit (typically below 2 mA/cm2 and above 5 mA/cm2). Plated gold stress measurement was carried out by wafer curvature comparison, before and after deposition, using Stoney´s formula for thin films1,2. A current density range between 1.5 and 6 mA/cm2 and temperature range between 50 and 70°C was investigated. Stress analysis was also carried out on a Cr-Au multilayer, which actually is the structural layer employed for gold microstructures: the multilayer consists of a chromium adhesion layer, a PVD gold seed layer and a plated gold layer, with thickness respectively 10 nm, 150 nm and 1500 nm. A range of stress was obtained, varying from tensile to compressive: cyanide bath yielded stress from -30 MPa to about 0 MPa, and sulfite bath showed stress between -90 MPa and 110 MPa. Stress variation induced by thermal treatments after deposition was also investigated, by examining the effect of photoresist sacrificial etching on the internal stress of chromium-gold structural layers: the final stress was about 180 MPa tensile for all samples, regardless the as-deposited stress, with a variation ranging from about 80 MPa to more than 200 MPa.
Keywords :
adhesion; chromium; crystal microstructure; current density; electroplating; etching; gold; heat treatment; internal stresses; micromachining; photoresists; stress analysis; stress measurement; surface roughness; tensile strength; thin films; yield stress; 10 nm; 150 nm; 1500 nm; 50 to 70 degC; Cr-Au; CrAu multilayer; MEMS; PVD; Stoney formula; chromium adhesion layer; chromium-gold structural layers; current density; cyanide bath yielded stress; cyanide-gold salt; electroplated gold films; electroplated gold layers; etching; gold microstructures; internal stress; low temperature surface micromachining; photoresist; plating solutions; plating temperature; stress analysis; stress measurement; sulfite-gold; surface roughness; tensile-compressive stress; thermal treatments; Compressive stress; Current density; Gold; Internal stresses; Micromachining; Rough surfaces; Surface roughness; Temperature; Tensile stress; Thermal stresses;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Design, Test, Integration and Packaging of MEMS/MOEMS 2003. Symposium on
Print_ISBN :
0-7803-7066-X
Type :
conf
DOI :
10.1109/DTIP.2003.1287077
Filename :
1287077
Link To Document :
بازگشت