DocumentCode
2835732
Title
A novel differential phase method to measure phase pattern and phase center of a horn antenna at 110 GHz
Author
Tuovinen, J. ; Lehto, A. ; Raisanen, A.
Author_Institution
Radio Lab., Helsinki Univ. of Technol., Espoo, Finland
fYear
1990
fDate
7-11 May 1990
Firstpage
1298
Abstract
The phase center location and the phase pattern for a 110 GHz corrugated horn were measured by a novel differential phase method. This method makes it possible to overcome problems associated with the complexity of the measurement setup and errors caused by the flexible cable or rotary joint required in the system. The phase center at 110 GHz is 2.7+or-0.3 mm from the aperture. The measurements agree very well with the results given by the modal matching technique. This technique predicts very accurately both the phase center position and the phase pattern.<>
Keywords
directive antennas; microwave measurement; phase measurement; waveguide antennas; 110 GHz; EHF; corrugate horn antenna; differential phase method; flexible cable; measurement setup; modal matching technique; phase center position; phase pattern; rotary joint; Antenna measurements; Feeds; Horn antennas; Oscillators; Phase measurement; Power harmonic filters; Rotation measurement; Testing; Transmitting antennas; Wavelength measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Antennas and Propagation Society International Symposium, 1990. AP-S. Merging Technologies for the 90's. Digest.
Conference_Location
Dallas, TX, USA
Type
conf
DOI
10.1109/APS.1990.115350
Filename
115350
Link To Document