Abstract :
Data from medical imaging system need to be analysed for diagnostics and clinical purposes. In a computerized system, the analysis normally involves classification process to determine disease and its condition. In an earlier work based on a database of 315 fundus images (FINDeRS), it is found that the foveal avascular zone (FAZ) enlargement strongly correlates with diabetic retinopathy (DR) progression having a correlation factor up to 0.883 at significant levels better than 0.01. However, it is also found that the FAZ areas can belong to different DR severity but with different levels of certainty having a Gaussian distribution. In this research work, the suitability of the Gaussian Bayes classifier in determining DR severity level is investigated. A v-fold cross-validation (VFCF) process is applied to the FINDeRS database to evaluate the performance of the classifier. It is shown that the classifier achieved sensitivity of >;84%, specificity of >;97% and accuracy of >;95% for all DR stages. At high values of sensitivity (>;95%), specificity (>;97%) and accuracy (>;98%) obtained for No DR and Severe NPDR/PDR stages, the Gaussian Bayes classifier is suitable as part of a computerised DR grading and monitoring system for early detection of DR and for effective treatment of severe cases.
Keywords :
Gaussian distribution; belief networks; diseases; eye; image classification; medical image processing; FINDeRS database; Gaussian Bayes classifier; Gaussian distribution; classification process; computerized system; cross-validation process; diabetic retinopathy; disease; foveal avascular zone enlargement; fundus images; grading; medical diagnosis; medical imaging system; monitoring system; severity level; Accuracy; Biomedical imaging; Databases; Diabetes; Pixel; Retinopathy; Sensitivity; Bayes classifier; Gaussian distribution; diabetic retinopathy; fundus image;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering and Sciences (IECBES), 2010 IEEE EMBS Conference on
Conference_Location :
Kuala Lumpur
Print_ISBN :
978-1-4244-7599-5
Type :
conf
DOI :
10.1109/IECBES.2010.5742198
Filename :
5742198
Link To Document :
بازگشت