    Effects of different zygomatic implant body surface roughness and implant length on stress distribution

  • Author

    Ishak, Muhammad Ikman ; Kadir, Mohammed Rafiq Abdul ; Sulaiman, Eshamsul ; Kassim, Norhayaty Abu

  • Author_Institution
    Med. Implant Technol. Group, Univ. Teknol. Malaysia, Skudai, Malaysia
  • fYear
    2010
  • fDate
    Nov. 30 2010-Dec. 2 2010
  • Firstpage
    210
  • Lastpage
    215
  • Abstract
    Among factors to contribute for the primary implant stability are implant design parameters as well as implant body surface condition. Through this study, the stress distribution within bone around implant will be investigated under variation of implant lengths and surface conditions by using three dimensional finite element analysis. Six finite element models involving three different zygomatic implant lengths -46.5 mm, 41.5 mm and 36.5 mm with a smooth surface and rough surface of implant body have been analyzed. Three dimensional models of craniofacial including soft tissue and prosthesis were constructed from computed tomography (CT) images datasets. The implant models were developed using computer-aided design (CAD) software and all models were analyzed via finite element analysis software. A 230N of vertical force was applied on top surface of prosthesis in second premolar region and a masseter load of 300N applied at zygomatic arch. The result showed that the increase of zygomatic implant length shows an ability to reduce both cortical and cancellous bone stress. Besides, the use of rough implant surface has resulted in reduction of stress value at bone-implant interface as well as at surrounding bone. The alveolar bone seems to play a lesser significant role in the zygomatic implant anchorage compared to the zygomatic bone.
  • Keywords
    biomechanics; bone; computerised tomography; finite element analysis; mechanical stability; medical image processing; physiological models; prosthetics; surface roughness; alveolar bone; body surface roughness; cancellous bone stress; computed tomography; computer-aided design software; cortical bone stress; craniofacial models; implant design parameters; implant length; primary implant stability; prosthesis; soft tissue; stress distribution; three dimensional finite element analysis; zygomatic implant; Analytical models; Biological system modeling; Bones; Implants; Materials; Rough surfaces; Surface roughness; atrophic maxilla; different lengths; edentulous; finite element analysis; surface roughness; zygomatic implant;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Sciences (IECBES), 2010 IEEE EMBS Conference on
  • Conference_Location
    Kuala Lumpur
  • Print_ISBN
    978-1-4244-7599-5
  • Type

    conf

  • DOI
    10.1109/IECBES.2010.5742230
  • Filename
    5742230