DocumentCode
2838008
Title
Evaluation of Harmonic Distortion under Unbalanced Supply Conditions
Author
Singh, Asheesh Kumar ; Singh, G.K. ; Mitra, R.
Author_Institution
Indian Inst. of Technol., Roorkee
fYear
2006
fDate
15-17 Dec. 2006
Firstpage
2569
Lastpage
2574
Abstract
This paper presents a detailed study on the effect of power system voltage unbalance on the harmonics injected by a ac-dc rectifier load. This study gives an insight about the role of sequence voltage components in voltage unbalance analysis. The simulations are carried out in time domain and the frequency spectra of the distorted waveform (input and output) are obtained using fast Fourier transform (FFT). The variation of different characteristic and non-characteristic harmonics with the degree of unbalance is also investigated. A full understanding of sensitivity of the current harmonic components to different unbalance voltage operating conditions is also obtained. A new terminology named as phase total harmonic distortion unbalance factor (PTHDUF) is introduced.
Keywords
fast Fourier transforms; harmonic distortion; power system harmonics; rectifiers; FFT; ac-dc rectifier load; current harmonic components; fast Fourier transform; phase total harmonic distortion unbalance factor; power system voltage unbalance; Delay effects; Frequency conversion; Harmonic analysis; Harmonic distortion; Power engineering and energy; Power harmonic filters; Power system harmonics; Power system simulation; Rectifiers; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Technology, 2006. ICIT 2006. IEEE International Conference on
Conference_Location
Mumbai
Print_ISBN
1-4244-0726-5
Electronic_ISBN
1-4244-0726-5
Type
conf
DOI
10.1109/ICIT.2006.372617
Filename
4237939
Link To Document