• DocumentCode
    2839522
  • Title

    DOI measurement with monolithic scintillation crystals: A primary performance evaluation

  • Author

    Lerche, Christoph W. ; Ros, Ana ; Gadea, Rafael ; Colom, Ricardo J. ; Toledo, Francisco J. ; Herrero, Vicente ; Monzó, José M. ; Sebastiá, Angel ; Abellan, Dori ; Sánchez, Filomeno ; Correcher, Carlos ; Gonzalez, Antonio J. ; Munar, Antoni ; Benlloch, Jos

  • Author_Institution
    Polytech. Univ. of Valencia, Valencia
  • Volume
    4
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    2594
  • Lastpage
    2600
  • Abstract
    We report a first assessment of image quality enhancement achieved by the implementation of depth of interaction detection with monolithic crystals. The method of interaction depth measurement is based on analogue computation of the standard deviation with an enhanced charge divider readout. This technique of depth of interaction detection was developed in order to provide fast and determination of this parameter at a reasonable increase of detector cost. The detector consists of an large-sized monolithic scintillator coupled to a position sensitive photomultiplier tube. A special design feature is the flat-topped pyramidal shape of the crystal. This reduces image compression near the edges of the scintillator. We studied the image enhancement qualitatively with a FDG filled hot spot phantom and quantitatively by displacing a single point source along a radial axis. An important uniformity improvement was observed for the reconstructed image of the hot spot phantom when depth of interaction correction was applied. A moderate improvement of the spatial resolution was observed when reconstructing the images of the point source with depth of interaction correction.
  • Keywords
    image enhancement; image reconstruction; medical image processing; phantoms; photomultipliers; position sensitive particle detectors; positron emission tomography; solid scintillation detectors; DOI measurement; depth-of-interaction detection; enhanced charge divider readout; image compression; image quality enhancement; image reconstruction; large-sized monolithic scintillator; monolithic scintillation crystals; phantom; position sensitive photomultiplier tube; positron emission tomography; Analog computers; Charge measurement; Costs; Crystals; Current measurement; Image quality; Image reconstruction; Imaging phantoms; Measurement standards; Solid scintillation detectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436680
  • Filename
    4436680