Title :
Comparison of in-beam and off-beam PET experiments at hard photons
Author :
Möckel, Daniela ; Kluge, Thomas ; Pawelke, Jörg ; Enghardt, Wolfgang
Author_Institution :
Inst. of Radiat. Phys., Dresden
fDate :
Oct. 26 2007-Nov. 3 2007
Abstract :
In-beam positron emission tomography (in-beam PET) is a valuable in situ method for quality assurance in radiation therapy. It is well investigated for therapy with carbon ions and has been successfully clinically implemented at the Gesellschaft fur Schwerionenforschung (GSI), Darmstadt, Germany. The extension of this efficient technique to other radiation treatment modalities may be worthwhile. For protons, 3He and 16O the feasibility has already been investigated. Furthermore, it seems to be feasible for the case of radiotherapy with high-energy photons, since positron emitters are generated by photons with energies above ~20 MeV due to (gamma, n) reactions (predominantly 11C and 15O in tissue). In this regard, promising conclusions have been obtained by Geant4 simulations as well as by off-beam PET experiments using a conventional PET scanner. The next step was the installation of a small double head positron camera consisting of two BGO block detectors at the irradiation site to measure the generated beta+ activity distribution simultaneously to the irradiation. The relation between deposited dose and beta+ activity density was quantified. The obtained results are presented and compared to that of off-beam PET experiments. Higher activities as well as an improved contrast between materials of different stoichiometry is achieved by measuring in-beam showing the advantage of in-beam PET over off-beam PET. Thus, the application of in-beam PET at radiation therapy with high-energy photons can be useful for quality assurance, comprising monitoring of dose delivery, patient positioning and tumor response.
Keywords :
dosimetry; positron emission tomography; radiation therapy; solid scintillation detectors; BGO block detectors; Geant4 simulations; PET scanner; dose delivery monitoring; double head positron camera; hard photon irradiation; in-beam positron emission tomography; off-beam positron emission tomography; radiation therapy; stoichiometry; Biomedical applications of radiation; Cameras; Carbon dioxide; Detectors; Helium; Medical treatment; Patient monitoring; Positron emission tomography; Protons; Quality assurance;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2007.4437028