DocumentCode
2845550
Title
Low-cost high-resolution 3rd generation PMT-quadrant- sharing (PQS) BGO block detectors for human and animal PET
Author
Liu, Shitao ; Liu, Jiguo ; Zhang, Yuxuan ; Li, Hongdi ; Ramirez, Rocio A. ; Wang, Yu ; Baghaei, Hossain ; Wong, Wai-Hoi
Author_Institution
Univ. of Texas, Houston
Volume
6
fYear
2007
fDate
Oct. 26 2007-Nov. 3 2007
Firstpage
4233
Lastpage
4236
Abstract
The objectives of this work were to investigate the light transport process of Photomultiplier-Quadrant-Sharing (PQS) detector block. The light transport process decides the signal shape and affects detector decoding and timing of detector blocks. We used DETECT2000, a Monte Carlo simulation program of the optical transport process, to study a 52 mm 13times13 crystal array size detector block The crystal was 3.92times3.92times20 mm3 size LSO crystal. Crystals was set to GROUND type surface and 1.8 refraction index. The reflector masks between crystals were set to 0.08 mm thickness, POLISH type surface and 97% reflection rate. The block was coupled to four 51 mm diameter PMT by PQS design. PMT window and optical grease refraction indexes were set to 1.5 and surfaces were set to transparent POLISH type. The PMT photocathode size was set to 47 mm diameter. Both the position and time distribution of the optical photons were got from the simulation. The optical photons were localized on photomultiplier (PMT) photocathode. In the position distribution of detected photons, the half maximum counts region were 17 mm2 on block corner and 362 mm2 on block center; the tenth maximum counts region were 64 mm2 on block corner and 1485 mm2 on the center. The region size changed according to reflectors on crystal side. The time spectrum of optical photons showed the rising time were 0.09~0.16 ns. The 95% light collection time were 1.14~1.96 ns.
Keywords
Monte Carlo methods; photocathodes; photomultipliers; positron emission tomography; solid scintillation detectors; DETECT2000; GROUND type surface; LSO crystal; Monte Carlo simulation; PET; PMT photocathode; PMT-quadrant-sharing block detector; POLISH type surface; detector decoding; light transport process; optical grease refraction index; optical transport process; photomultiplier; size 47 mm; size 51 mm; size 52 mm; Animals; Cathodes; Crystals; Detectors; Humans; Optical arrays; Optical refraction; Positron emission tomography; Shape; Signal processing;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location
Honolulu, HI
ISSN
1095-7863
Print_ISBN
978-1-4244-0922-8
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2007.4437052
Filename
4437052
Link To Document