• DocumentCode
    2849329
  • Title

    The Use of Wireless Transmission System in IMU Calibration

  • Author

    Yu, Xining ; Li, Jie ; Jiang, Qiao ; Du, Ying

  • Author_Institution
    Nat. Key Lab. for Electron. Meas., North Univ. of China, Taiyuan, China
  • Volume
    2
  • fYear
    2010
  • fDate
    13-14 Oct. 2010
  • Firstpage
    762
  • Lastpage
    764
  • Abstract
    In view of the engineering requirements for MEMS inertial devices, by using C8051F020 to build hardware platforms, the calibration of MIMU was completed before used through wireless transmission chip NRF24L01 to transfer experimental data. Data transmission tests were carried out with the designed hardware circuit. The results show that the scheme can achieve real-time data transmission accurately.
  • Keywords
    inertial navigation; micromechanical devices; C8051F020; MEMS inertial device; MIMU calibration; NRF24L01 chip; data transmission testing; hardware circuit design; wireless transmission system; Accelerometers; Calibration; Computers; Data communication; Hardware; Wireless communication; Wireless sensor networks; Calibration; Inertial Device; NRF24L01; Wireless transmission;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent System Design and Engineering Application (ISDEA), 2010 International Conference on
  • Conference_Location
    Changsha
  • Print_ISBN
    978-1-4244-8333-4
  • Type

    conf

  • DOI
    10.1109/ISDEA.2010.425
  • Filename
    5743521