  • Abstract
    In this paper, a portable low-cost long- time one lead Electrocardiogram (ECG) Monitor is present, which is powered by one dry battery and based on NUC501. Power management module, analogous amplifier and Advanced RISC Machines (ARM) are used in hardware design. While hardware driver, digital filter, modified baseline drift method and difference threshold method are taken in software structure. The monitor gathers ECG signal through cable from user´s body. A prototype instrument has been finally produced and will be put into the clinical environment. The notch filter and median filter are used to process the data. His/her ECG tracing is displayed lively on Liquid Crystal Display (LCD) screen. Also the heart rate is shown precisely on LCD screen and displayed with led flashing. The monitor also can storage and transport data to computer through Universal Serial Bus (USB) cable. While being powered by one dry battery, it works twenty-four hours. If there is any abnormally changes of heart rate, this instrument will be given alarm through the buzzer. The testing results show that this monitor is low power consumption, light-weight, accurate and low-cost. It can care for cardiac patients very good and provide a reliable cost-effective choice for cardio-path.
  • Keywords
    amplifiers; cardiology; digital filters; electrocardiography; energy management systems; liquid crystal displays; median filters; reduced instruction set computing; LCD screen; NUC501; USB cable; advanced RISC machines; analogous amplifier; cardiac patients; cardiopath; difference threshold method; digital filter; electrocardiogram monitor; hardware design; hardware driver; liquid crystal display; long-time recording; median filter; modified baseline drift method; notch filter; portable one lead ECG monitor; power management module; software structure; universal serial bus; Batteries; Computerized monitoring; Electrocardiography; Energy management; Filters; Hardware; Heart rate; Instruments; Power amplifiers; Universal Serial Bus; Difference Threshold Method; Digital filter; ECG; Long-time; NUC501;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control and Decision Conference (CCDC), 2010 Chinese
  • Conference_Location
    Xuzhou
  • Print_ISBN
    978-1-4244-5181-4
  • Electronic_ISBN
    978-1-4244-5182-1
  • Type

    conf

  • DOI
    10.1109/CCDC.2010.5499069
  • Filename
    5499069