Inverse planning incorporating organ motion
Author :
Li, Jonathan G. ; Xing, Lei
Author_Institution :
Dept. of Radiat. Oncology, Stanford Univ., CA, USA
Volume :
4
fYear :
2000
fDate :
2000
Firstpage :
3269
Abstract :
Accurate targeting is important in intensity-modulated radiation therapy (IMRT). The positional uncertainties of structures arise mainly from random organ motion and patient setup errors. While it is important to improve immobilization and reduce the influence of organ motion, the residual effects should be included in the IMRT plan design. Current inverse planning algorithms follow the conventional approach by assuming population-based margins to the target and sensitive structures. Margin around a structure represents a “hard boundary” and the fact that a structure has a spatial probability distribution has been completely ignored. With increasing understanding of spatial uncertainties of structures and the technical capability of fine-tuning the dose distribution on an individual beamlet level in IMRT, it seems timely and important to utilize the information in the planning process. The authors describe an inverse planning algorithm which takes into consideration positional uncertainty in terms of spatial probability distribution. The algorithm was demonstrated by assuming that the random organ motion was represented by a 3D Gaussian distribution function. Other probability distributions can be dealt with similarly. In particular, the commonly used “hard margin” is a special case of the current approach with a uniform probability distribution within a specified range. The algorithm was applied to plan treatment for a prostate case and a pancreatic case. The results were compared with those obtained by adding a margin to the clinical target volume. Better sparing of the sensitive structures were obtained in both cases using the proposed method for approximately the same target coverage
Keywords :
biological organs; biomechanics; dosimetry; radiation therapy; accurate targeting; clinical target volume; hard boundary; intensity-modulated radiation therapy; inverse planning; organ motion; pancreatic case; patient setup errors; population-based margins; prostate case; random organ motion; residual effects; sensitive structures sparing; spatial uncertainties; structures positional uncertainties; target structures; Biomedical applications of radiation; Collimators; Gaussian distribution; Intensity modulation; Medical treatment; Pancreas; Probability distribution; Process planning; Thorax; Uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1094-687X
Print_ISBN :
0-7803-6465-1
Type :
conf
DOI :
10.1109/IEMBS.2000.901665