DocumentCode
2858759
Title
Study on a New Way of Load-matched for Voltage-Source Induction Heating Inverters
Author
Jingang, Li ; Yanru, Zhong ; Xin, Ma
Author_Institution
Sch. of Autom. & Inf. Eng., Xi´´an Jiaotong Univ.
fYear
2006
fDate
24-26 May 2006
Firstpage
1
Lastpage
5
Abstract
The characteristics of three types of three-order resonant circuits, which were used in static electricity induction load-matched for voltage-source induction heating inverter is presented in this paper. The type of LCL is of more advantages. The analysing results and the designing way of LCL were given. The static state characters of this circuit were analyzed in detail and the characters curves were protracted with MATALB. The simulation and experimental results proved the theoretic analysis. Some guidance suggestions for voltage-source induction heating load-matched were also provided
Keywords
electrostatics; induction heating; resonant invertors; MATALB; static electricity load-matching; three-order resonant circuits; voltage-source induction heating inverters; Circuit topology; Coils; Frequency; Inverters; RLC circuits; Resistance heating; Resonance; Switches; Voltage; Water heating;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics and Applications, 2006 1ST IEEE Conference on
Conference_Location
Singapore
Print_ISBN
0-7803-9513-1
Electronic_ISBN
0-7803-9514-X
Type
conf
DOI
10.1109/ICIEA.2006.257099
Filename
4025717
Link To Document