• DocumentCode
    2858807
  • Title

    A translation method for ladder diagram with application to a manufacturing process

  • Author

    Kim, Hyung Seok ; Kwon, Wook Hyun ; Chang, Naehyuck

  • Author_Institution
    ERC for Adv. Control Instrum., Seoul Nat. Univ., South Korea
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    793
  • Abstract
    This paper proposes a translation method for programmable logic controllers (PLCs) used in most automation systems. It describes detailed steps of the method that converts from a ladder diagram directly to a native code. A general-purpose DSP (digital signal processor) based PLC with the translation method is implemented. A benchmark test in an automotive manufacturing process shows that the proposed translation method fairly speeds up the execution in comparison with existing interpretation methods
  • Keywords
    automobile industry; manufacturing processes; program interpreters; programmable controllers; PLC; automotive industry; digital signal processor; ladder diagram; manufacturing process; programmable logic controllers; translation method; Application software; Application specific integrated circuits; Automotive engineering; Computer aided manufacturing; Instruments; Manufacturing automation; Manufacturing processes; Production; Programmable control; Reduced instruction set computing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Robotics and Automation, 1999. Proceedings. 1999 IEEE International Conference on
  • Conference_Location
    Detroit, MI
  • ISSN
    1050-4729
  • Print_ISBN
    0-7803-5180-0
  • Type

    conf

  • DOI
    10.1109/ROBOT.1999.770071
  • Filename
    770071