DocumentCode
2859056
Title
Impact of cavity RF field phase and amplitude control uncertainties on the SNS linac
Author
Jeon, D. ; Stovall, J. ; Takeda, H. ; Crandall, K.
Author_Institution
SNS Project, Oak Ridge Nat. Lab., TN, USA
Volume
5
fYear
2003
fDate
12-16 May 2003
Firstpage
2855
Abstract
There is an accuracy limit of LLRF control over cavity rf phase and amplitude. This limited accuracy of control gives rise to beam energy and phase jitter, emittance growth, and beam loss. In the case of the SNS linac, there are a few limiting factors such as minimizing injection foil miss, acceptable ring injection painting, and beam loss in the linac which are related with the LLRF control errors. We studied the impact of ±1° / ±1% and ±0.5° / ±0.5% rf phase and amplitude uncertainties to the linac using the Ltrace and Parmila codes.
Keywords
accelerator RF systems; accelerator cavities; beam handling techniques; jitter; linear accelerators; proton accelerators; LLRF control; Ltrace code; Parmila code; SNS linac; amplitude control uncertainties; beam energy; beam loss; cavity RF field phase; emittance growth; injection foil; phase jitter; ring injection painting; Degradation; Error correction; Histograms; Jitter; Laboratories; Linear particle accelerator; Painting; Particle beam injection; Radio frequency; Uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
ISSN
1063-3928
Print_ISBN
0-7803-7738-9
Type
conf
DOI
10.1109/PAC.2003.1289744
Filename
1289744
Link To Document