• DocumentCode
    2859056
  • Title

    Impact of cavity RF field phase and amplitude control uncertainties on the SNS linac

  • Author

    Jeon, D. ; Stovall, J. ; Takeda, H. ; Crandall, K.

  • Author_Institution
    SNS Project, Oak Ridge Nat. Lab., TN, USA
  • Volume
    5
  • fYear
    2003
  • fDate
    12-16 May 2003
  • Firstpage
    2855
  • Abstract
    There is an accuracy limit of LLRF control over cavity rf phase and amplitude. This limited accuracy of control gives rise to beam energy and phase jitter, emittance growth, and beam loss. In the case of the SNS linac, there are a few limiting factors such as minimizing injection foil miss, acceptable ring injection painting, and beam loss in the linac which are related with the LLRF control errors. We studied the impact of ±1° / ±1% and ±0.5° / ±0.5% rf phase and amplitude uncertainties to the linac using the Ltrace and Parmila codes.
  • Keywords
    accelerator RF systems; accelerator cavities; beam handling techniques; jitter; linear accelerators; proton accelerators; LLRF control; Ltrace code; Parmila code; SNS linac; amplitude control uncertainties; beam energy; beam loss; cavity RF field phase; emittance growth; injection foil; phase jitter; ring injection painting; Degradation; Error correction; Histograms; Jitter; Laboratories; Linear particle accelerator; Painting; Particle beam injection; Radio frequency; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
  • ISSN
    1063-3928
  • Print_ISBN
    0-7803-7738-9
  • Type

    conf

  • DOI
    10.1109/PAC.2003.1289744
  • Filename
    1289744