DocumentCode :
2859056
Title :
Impact of cavity RF field phase and amplitude control uncertainties on the SNS linac
Author :
Jeon, D. ; Stovall, J. ; Takeda, H. ; Crandall, K.
Author_Institution :
SNS Project, Oak Ridge Nat. Lab., TN, USA
Volume :
5
fYear :
2003
fDate :
12-16 May 2003
Firstpage :
2855
Abstract :
There is an accuracy limit of LLRF control over cavity rf phase and amplitude. This limited accuracy of control gives rise to beam energy and phase jitter, emittance growth, and beam loss. In the case of the SNS linac, there are a few limiting factors such as minimizing injection foil miss, acceptable ring injection painting, and beam loss in the linac which are related with the LLRF control errors. We studied the impact of ±1° / ±1% and ±0.5° / ±0.5% rf phase and amplitude uncertainties to the linac using the Ltrace and Parmila codes.
Keywords :
accelerator RF systems; accelerator cavities; beam handling techniques; jitter; linear accelerators; proton accelerators; LLRF control; Ltrace code; Parmila code; SNS linac; amplitude control uncertainties; beam energy; beam loss; cavity RF field phase; emittance growth; injection foil; phase jitter; ring injection painting; Degradation; Error correction; Histograms; Jitter; Laboratories; Linear particle accelerator; Painting; Particle beam injection; Radio frequency; Uncertainty;