  • Abstract
    After a component has experienced problems in the field, a new design would be introduced to eliminate/reduce the probability of the same failure. With limited experience on the new configuration in the field/test, a question, which always needs to be answered by the reliability engineer, is that: is the new one better than the old? The new component has accumulated certain operating hours in the field/test. Few failures or (most of the time) no failures have been observed. The customer cannot wait. The problem is to determine whether the reliability of the component is improved significantly with the new design. There was no analytical method existing for the studied case. Based on the Weibayes idea, a statistical approach is developed to calculate the confidence level at which the null hypothesis, that two data sets come from the same parent population, will be rejected. A case study is provided to demonstrate/illustrate the proposed approach. It is simple and accurate. The method appears to be the best available method for the studied case
  • Keywords
    Bayes methods; Weibull distribution; design engineering; failure analysis; reliability; Weibayes method; case study; component reliability; confidence level; designs; failures; null hypothesis; operating hours; probability; statistical approach; Best practices; Design engineering; Failure analysis; Manufacturing; Reliability engineering; Testing; Turbines; Weibull distribution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability and Maintainability Symposium, 2001. Proceedings. Annual
  • Conference_Location
    Philadelphia, PA
  • ISSN
    0149-144X
  • Print_ISBN
    0-7803-6615-8
  • Type

    conf

  • DOI
    10.1109/RAMS.2001.902487
  • Filename
    902487