Title :
A fault-tolerant technique for Delta-connected vector-control AC motor-drives
Author :
Sayed-Ahmed, Ahmed ; Mirafzal, Behrooz ; Demerdash, Nabeel A O
Abstract :
A fault-tolerant technique valid for both open-loop and vector-control motor-drive systems is introduced in this paper. The technique is merely presented for AC motors with Delta-connected circuits in their stator windings. Hence, it enables the operation of the three phase motor upon a failure in one of its phases without the need of a special fault detection algorithm. This technique is to significantly mitigate torque pulsations, which are caused by an open-Delta configuration in the stator windings. The performance of the fault-tolerant technique was experimentally verified using a 5-hp 460V induction motor-drive system and the results are presented in this paper.
Keywords :
fault tolerance; induction motor drives; machine control; stators; torque; AC motor-drives; delta-connected circuits; fault detection; fault-tolerant technique; induction motor-drive; open-loop motor-drive; stator windings; three phase motor; torque pulsation mitigation; vector-control motor-drive; voltage 460 V; Circuit faults; Induction motors; Stator windings; Torque; Windings; AC motordrives; Delta-connected stator windings; Torque pulsations; closed-loop vector-control drives; fault tolerant; induction motor; open-Delta; stator failure; stator fault mitigation; stator-unbalance; volt-per-hertz (scalar) control method;
Conference_Titel :
Applied Power Electronics Conference and Exposition (APEC), 2011 Twenty-Sixth Annual IEEE
Conference_Location :
Fort Worth, TX
Print_ISBN :
978-1-4244-8084-5
DOI :
10.1109/APEC.2011.5744722