DocumentCode :
2868384
Title :
Steady-state analysis of a LCC-type load commutated high-frequency inverter
Author :
Bhat, A.K.S. ; Dewan, S.B.
Author_Institution :
Dept. of Electr. Eng., Victoria Univ., BC, Canada
fYear :
1988
fDate :
11-14 April 1988
Firstpage :
1220
Abstract :
The steady-state analysis of a high-frequency resonant (load commutated) inverter, which used an LCC-type commutation circuit is presented. The difference modes of operation are explained. A Fourier series method is used to analyze the circuit under steady-state conditions for continuous-current mode operation. The analysis is used to predict the performance of the inverter and to develop the design curves for the selection of inverter components. A simple design procedure is presented and illustrated. The predicted performance of the inverter agrees closely with results for a prototype experimental unit.<>
Keywords :
commutation; invertors; Fourier series method; LCC-type commutation circuit; continuous-current mode operation; design procedure; high-frequency inverter; load commutation; performance; steady-state analysis; Fourier series; Frequency conversion; Inductance; Performance analysis; RLC circuits; Resonance; Resonant frequency; Resonant inverters; Steady-state; Switching circuits;