• DocumentCode
    2868961
  • Title

    Detection of faults in PMSM using Field Reconstruction Method and Mechanical Impulse Response

  • Author

    Kiani, M. ; Torregrossa, D. ; Fahimi, B. ; Peyraut, F. ; Miraoui, A.

  • fYear
    2011
  • fDate
    6-11 March 2011
  • Firstpage
    1896
  • Lastpage
    1901
  • Abstract
    A novel approach for quick evaluation of the electromagnetically induced vibration in a Permanent Magnet Synchronous Machine (PMSM) is introduced. Field Reconstruction Method (FRM) and Mechanical Impulse Response (MIR) are used for this purpose. The electromagnetic forces and vibration emissions are analyzed in time and frequency domain for healthy and faulty cases. These analyses allow for detecting specific properties of forces and vibration which are later on used for identifying various fault conditions. The proposed concept has been experimentally verified. Comparison of the vibration emissions for different operating conditions under various types of faults are presented as well.
  • Keywords
    permanent magnet machines; synchronous machines; transient response; PMSM; electromagnetic forces; electromagnetically induced vibration; faults detection; field reconstruction method; mechanical impulse response; permanent magnet synchronous machine; Circuit faults; Demagnetization; Electromagnetic forces; Harmonic analysis; Stators; Velocity control; Vibrations; 3D FEM mechanical analysis; diagnosis; fault; field reconstruction method; mechanical impulse response;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition (APEC), 2011 Twenty-Sixth Annual IEEE
  • Conference_Location
    Fort Worth, TX
  • ISSN
    1048-2334
  • Print_ISBN
    978-1-4244-8084-5
  • Type

    conf

  • DOI
    10.1109/APEC.2011.5744854
  • Filename
    5744854