DocumentCode
2870665
Title
Reference Values for Dynamic Calibration of PMUs
Author
Stenbakken, Gerard ; Nelson, Tom ; Zhou, Ming ; Centeno, Virgilio
Author_Institution
Nat. Inst. of Stand. & Technol., Gaithersburg
fYear
2008
fDate
7-10 Jan. 2008
Firstpage
171
Lastpage
171
Abstract
This paper discusses measurements of the dynamic performance of electric power phaser measurement units, PMUs, and their relation to the requirements of the IEEE synchrophasor standard C37.118-2005. In particular, it proposes a new method for monitoring the dynamic power signals that change in amplitude and frequency during the testing of PMUs. The new method estimates the reference values for dynamic power signals so they can be compared with the PMU values to determine the PMU\´s errors. This requires estimating the "true" timestamped values of dynamic power signals with low uncertainty. The paper also discusses the issue of aliasing of sampled dynamic signals, and the relationship between the requirement in the standard to reject an out of band or interharmonic signal and dynamic signal performance.
Keywords
calibration; phase measurement; power system measurement; IEEE synchrophasor standard C37.118-2005; dynamic calibration; dynamic power signal monitoring; electric power phaser measurement units; interharmonic signal; sampled dynamic signals aliasing; Calibration; Electric variables measurement; Frequency; Measurement standards; Measurement units; Monitoring; Phase measurement; Phasor measurement units; Power measurement; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Hawaii International Conference on System Sciences, Proceedings of the 41st Annual
Conference_Location
Waikoloa, HI
ISSN
1530-1605
Type
conf
DOI
10.1109/HICSS.2008.370
Filename
4438874
Link To Document