DocumentCode :
287136
Title :
Optimal performance of double output induction generator used in WECS
Author :
Eskander, M.N. ; El Hagry, M.T.
Author_Institution :
Electron. Res. Inst., Cairo, Egypt
fYear :
1993
fDate :
13-16 Sep 1993
Firstpage :
276
Lastpage :
281
Abstract :
A new technique for optimizing the power generated by a double output induction generator (DOIG) is established. The proposed control strategy ensures stable operation of the DOIG within a wide speed range without overheating the machine. The proposed scheme employed a controllable rectifier, a DC link, an inverter, and an isolating transformer in the rotor circuit. Variation of firing angles, overlap angle, voltages, and powers with speed are deduced. Experimental results are given. Results showed that twice the rated machine power is generated at S=-1
Keywords :
asynchronous generators; invertors; machine control; rectifying circuits; wind turbines; DC link; control strategy; controllable rectifier; double output induction generator; firing angles; isolating transformer; overlap angle; rotor circuit;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics and Applications, 1993., Fifth European Conference on
Conference_Location :
Brighton
Type :
conf
Filename :
264842
Link To Document :
بازگشت