Title :
Modeling of capacitive and electromagnetic field shielding effects in a CVT
Author :
Sommerville, William ; Gover, James ; Sanchez, Robert ; Bou, Jimmy
Author_Institution :
Kettering Univ., Flint, MI
Abstract :
In the discharge of a capacitor the current was measured with a current viewing transformer (CVT). In addition to measuring the current flowing through the CVT primary, a 51 MHz noise signal was added to the primary current. When the CVT was covered with a gold shield, the noise was eliminated. Analysis of the measured results indicate that the gold layer reflected the electromagnetic that was generated by current flowing in the primary and that the capacitance between the shield and the CVT secondary had no measurable effect on the CVT output
Keywords :
capacitors; current transformers; electric current measurement; electromagnetic coupling; electromagnetic shielding; interference suppression; 51 MHz; CVT; capacitive shielding; capacitor discharge; current measurement; current viewing transformer; electromagnetic field coupling; electromagnetic field shielding; gold shield; signal noise elimination; Capacitance measurement; Capacitors; Current measurement; Electromagnetic analysis; Electromagnetic fields; Electromagnetic measurements; Electromagnetic modeling; Electromagnetic shielding; Gold; Noise measurement;
Conference_Titel :
Electrical Insulation Conference and Electrical Manufacturing Expo, 2005. Proceedings
Conference_Location :
Indianapolis, IN
Print_ISBN :
0-7803-9145-4
DOI :
10.1109/EEIC.2005.1566324