• DocumentCode
    287727
  • Title

    Calibration of high frequency imaging deformable towed arrays

  • Author

    Florin, F.

  • Author_Institution
    Thomson Sintra ASM, Brest, France
  • Volume
    1
  • fYear
    1994
  • fDate
    13-16 Sep 1994
  • Abstract
    Using synthetic aperture arrays or flexible towed arrays for side scan sonar high frequency imaging may improve performance. Both systems are characterized by an uncertainty on sensors positions. The author presents a way to treat the array shape recovering problem for those applications. Required specifications for synthetic aperture sonar and towed array sonar are compared. The tolerances on shape distortions are considered for array calibration. Ways to calibrate the distorted towed arrays, in order to ensure well-focussed imaging, are described. Calibration and self-calibration methods are presented
  • Keywords
    array signal processing; calibration; oceanographic techniques; sonar arrays; sonar imaging; array shape recovery problem; calibration methods; flexible towed arrays; focussing; high frequency imaging deformable towed arrays; sensor position uncertainty; shape distortions; side scan sonar; synthetic aperture arrays; towed array sonar; Calibration; Chromium; Frequency; High-resolution imaging; Sensor arrays; Sensor phenomena and characterization; Shape; Spatial resolution; Synthetic aperture sonar; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    OCEANS '94. 'Oceans Engineering for Today's Technology and Tomorrow's Preservation.' Proceedings
  • Conference_Location
    Brest
  • Print_ISBN
    0-7803-2056-5
  • Type

    conf

  • DOI
    10.1109/OCEANS.1994.363844
  • Filename
    363844