  • Abstract
    Changes in the longitudinal impedance budget occur due to the changes in the machine structure. Following the installation in ELETTRA storage ring of the new vacuum chambers in the last three years, estimation of the longitudinal loss factor are carried out. The measurements are performed by mapping the horizontal closed orbit deviation, taking full advantage of the newly installed high resolution BPM electron system. The current results are compared with those of the previous measurements and presented in this paper.
  • Keywords
    electron accelerators; particle beam diagnostics; storage rings; ELETTRA storage ring; beam position monitor; high resolution BPM electron system; longitudinal impedance budget; longitudinal loss factor; vacuum chambers; Charge measurement; Current measurement; Electron beams; Elementary particle vacuum; Energy loss; Energy measurement; Extraterrestrial measurements; Impedance; Loss measurement; Storage rings;