• DocumentCode
    2878902
  • Title

    Forward-nulling passive millimeter wave imaging using cooling water-wall

  • Author

    Sato, Hikaru ; Sawaya, Kunio

  • Author_Institution
    Grad. Sch. of Eng., Tohoku Univ., Sendai, Japan
  • fYear
    2013
  • fDate
    7-13 July 2013
  • Firstpage
    810
  • Lastpage
    811
  • Abstract
    A cooling water-wall room is developed and the forward-nulling passive millimeter-wave (PMMW) imaging is performed using developed room. It is shown experimentally that high-quality of PMMW images is obtained by the presence of the cooling water-wall room which works as a nulling source and a shielding wall.
  • Keywords
    cooling; millimetre wave imaging; shielding; PMMW images; cooling water-wall room; forward-nulling passive millimeter wave imaging; nulling source; shielding wall; Brightness temperature; Cooling; Dielectrics; Imaging; Millimeter wave technology; Thermal conductivity; Thermal noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation Society International Symposium (APSURSI), 2013 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1522-3965
  • Print_ISBN
    978-1-4673-5315-1
  • Type

    conf

  • DOI
    10.1109/APS.2013.6711064
  • Filename
    6711064