DocumentCode
2878923
Title
Correlation between the field strength measurement and the absorbing clamp measurement
Author
Ishizu, Masaya ; Urabe, Junichiro ; Fujii, Katsumi ; Sugiura, Akira
Author_Institution
Res. Inst. of Electr. Commun., Tohoku Univ., Sendai
fYear
2006
fDate
1-4 Aug. 2006
Firstpage
189
Lastpage
192
Abstract
In the frequency range of 30 to 300 MHz, radiated disturbances from electronic equipment are usually measured with an antenna. In contrast, disturbances of a household appliance are evaluated using an absorbing clamp attached on the mains cable. Hence, theoretical and experimental investigations are carried out on the correlation between the field strength measurement and the absorbing clamp measurement
Keywords
VHF antennas; field strength measurement; power system measurement; radiofrequency interference; 30 to 300 MHz; absorbing clamp measurement; antenna; electronic equipment; field strength measurement; household appliance; radiated disturbances; Antenna measurements; Area measurement; Cable shielding; Clamps; Current measurement; Electric variables measurement; Electronic equipment; Frequency measurement; Open area test sites; Receiving antennas;
fLanguage
English
Publisher
ieee
Conference_Titel
Environmental Electromagnetics, The 2006 4th Asia-Pacific Conference on
Conference_Location
Dalian
Print_ISBN
1-4244-0183-6
Type
conf
DOI
10.1109/CEEM.2006.257933
Filename
4027265
Link To Document