• DocumentCode
    2878964
  • Title

    Design and performance of the LCLS cavity BPM system

  • Author

    Lill, R. ; Norum, W. ; Morrison, L. ; Sereno, N. ; Waldschmidt, G. ; Walters, D. ; Smith, S. ; Straumann, T.

  • Author_Institution
    Argonne Nat. Lab., Argonne
  • fYear
    2007
  • fDate
    25-29 June 2007
  • Firstpage
    4366
  • Lastpage
    4368
  • Abstract
    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM010 monopole reference cavity and a TM110 dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low- noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.
  • Keywords
    accelerator cavities; beam handling techniques; particle beam diagnostics; phase locked oscillators; prototypes; receivers; wigglers; LCLS cavity BPM system; LCLS undulator; beam position monitor system; dipole cavity; frequency 11.384 GHz; heterodyne receiver; high-resolution X-band cavity; phase locking local oscillator; prototype; signal processing electronics; Band pass filters; Data acquisition; Detectors; Electromagnetic interference; Electron beams; Frequency; Instruments; Local oscillators; Surface impedance; Undulators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2007. PAC. IEEE
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0916-7
  • Type

    conf

  • DOI
    10.1109/PAC.2007.4440010
  • Filename
    4440010