DocumentCode
2879253
Title
IPM measurements in the Tevatron
Author
Jansson, A. ; Bowie, K. ; Fitzpatrick, T. ; Kwarciany, R. ; Lundberg, C. ; Slimmer, D. ; Valerio, L. ; Zagel, J.
Author_Institution
Fermilab, Batavia
fYear
2007
fDate
25-29 June 2007
Firstpage
3883
Lastpage
3885
Abstract
Two ionization profile monitors (IPMs) were installed in the Tevatron in 2006. The detectors are capable of resolving single bunches turn-by-turn. This paper presents recent improvements to the system hardware and its use for beam monitoring. In particular, the correction of beam size oscillations observed at injection is discussed.
Keywords
particle beam bunching; particle beam diagnostics; particle beam dynamics; particle beam injection; Tevatron; beam bunches; beam injection; beam monitoring; beam size oscillations; ionization profile monitors; Clocks; Detectors; Ionization; Microprogramming; Optical buffering; Production systems; Protons; Prototypes; Radio frequency; Size measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0916-7
Type
conf
DOI
10.1109/PAC.2007.4440026
Filename
4440026
Link To Document