• DocumentCode
    2879302
  • Title

    Method for Creating Low Cost 3D MEMS Chemical Sensors by Using Through Wafer VIAS and Wafer Bonding

  • Author

    Wagner, Mark ; Zou, Jin

  • Author_Institution
    Sensorcon, Inc., Reading
  • fYear
    2007
  • fDate
    May 29 2007-June 1 2007
  • Firstpage
    1119
  • Lastpage
    1126
  • Abstract
    For some MEMS based chemical sensors, it is desirable to incorporate 3D features such as enclosed reaction chambers and both chemical & electrical I/O. Like most other MEMS devices, it is preferential to create all of these features at the wafer level. Although wafer level integration has the potential to simplify back-end & packaging requirements, improve device performance, and reduce size & cost, developing reliable processes is a significant challenge. This paper reviews our process development efforts, including some practical tips and tricks for prototyping MEMS in an R&D environment. Test devices specifically designed to assess the key processes of low cost through wafer via creation and thermocompression wafer bonding were fabricated and characterized by simple electrical and mechanical testing. Process implications are offered for both the chemical sensors of interest as well as other MEMS devices.
  • Keywords
    chemical sensors; microsensors; wafer bonding; wafer-scale integration; 3D MEMS chemical sensors; electrical-mechanical testing; thermocompression wafer bonding; wafer VIAS; wafer level integration; Chemical sensors; Costs; Flip chip; Microelectromechanical devices; Micromechanical devices; Packaging; Space technology; Testing; Wafer bonding; Wafer scale integration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Components and Technology Conference, 2007. ECTC '07. Proceedings. 57th
  • Conference_Location
    Reno, NV
  • ISSN
    0569-5503
  • Print_ISBN
    1-4244-0985-3
  • Electronic_ISBN
    0569-5503
  • Type

    conf

  • DOI
    10.1109/ECTC.2007.373936
  • Filename
    4250022