• DocumentCode
    2880717
  • Title

    Design, construction and commissioning of the SuSI ECR

  • Author

    Zavodszky, P.A. ; Arend, B. ; Cole, D. ; DeKamp, J. ; Machicoane, G. ; Marti, F. ; Miller, P. ; Moskalik, J. ; Nurnberger, W. ; Ottarson, J. ; Vincent, J. ; Wu, X. ; Zeller, A.

  • Author_Institution
    Michigan State Univ., East Lansing
  • fYear
    2007
  • fDate
    25-29 June 2007
  • Firstpage
    3766
  • Lastpage
    3770
  • Abstract
    An electron cyclotron resonance ion source (ECRIS) was constructed at the NSCL/MSU to replace the existing SC-ECRIS. This ECRIS operates at 18+14.5 GHz microwave frequencies and it is planned an upgrade to 24-28 GHz in the second phase of commissioning. A superconducting hexapole coil system produces the radial magnetic field; the axial trapping is produced with six superconducting solenoids enclosed in an iron yoke to allow tuning the distance between the plasma electrode and resonant zone in the plasma. We report the details of the design, construction and initial commissioning results of this new ECIS.
  • Keywords
    accelerator RF systems; beam handling equipment; cyclotron resonance; ion sources; superconducting coils; superconducting magnets; SUSI ECR; axial trapping; electron cyclotron resonance ion source; superconducting hexapole coil system; superconducting solenoids; Cyclotrons; Electrons; Ion sources; Magnetic fields; Magnetic resonance; Microwave frequencies; Plasmas; Solenoids; Superconducting coils; Superconducting microwave devices;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2007. PAC. IEEE
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0916-7
  • Type

    conf

  • DOI
    10.1109/PAC.2007.4440110
  • Filename
    4440110