Title :
A Controlled-Capacity Power Unit for High-Density Backplane Protection
Author :
Herbert, A.S. ; Peterson, W.A.
Author_Institution :
Bell Laboratories, Whippany, New Jersey 07981
Abstract :
Signal-carrying conductors located near power conductors can be damaged by fault currents. Previously, these signal conductors have been protected in high-density backplanes by segmenting the load and limiting the current available per segment to a safe level using one of three methods: current-limited power supplies, electronic monitors in the power distribution network, or distribution fuses. This paper describes a system that uses a controlled-capacity power unit to protect signal conductors without the inherent expense of segmentation.
Keywords :
Backplanes; Central Processing Unit; Circuits; Conductors; Control systems; Fault currents; Fuses; Power supplies; Power system protection; Steady-state;
Conference_Titel :
Telecommunications Energy Conference, 1982. INTELEC 1982. International
Conference_Location :
Washington, DC, USA
DOI :
10.1109/INTLEC.1982.4793717