DocumentCode :
2883110
Title :
New corrector system for the Fermilab Booster
Author :
Prebys, E.J. ; Drennan, C.C. ; Harding, D.J. ; Kashikhin, V. ; Lackey, J.R. ; Makarov, A. ; Pellico, W.A.
Author_Institution :
FNAL, Batavia
fYear :
2007
fDate :
25-29 June 2007
Firstpage :
467
Lastpage :
469
Abstract :
We present an ambitious ongoing project to build and install a new corrector system in the Fermilab 8 GeV booster. The system consists of 48 corrector packages, each containing horizontal and vertical dipoles, normal and skew quadrupoles, and normal and skew sextupoles. Space limitations in the machine have motivated a unique design, which utilizes custom wound coils around a 12 pole laminated core. Each of the 288 discrete multipole elements in the system will have a dedicated power supply, the output current of which is controlled by an individual programmable ramp. This paper describes the physics considerations which drove the design, as well as issues in the control of the system.
Keywords :
particle accelerator accessories; synchrotrons; Fermilab Booster; corrector system; dipoles; electron volt energy 8 GeV; quadrupoles; sextupoles; Acceleration; Coils; Control systems; Current supplies; Magnets; Packaging machines; Particle beams; Prototypes; Resonance; Wounds;
fLanguage :
English