Abstract :
As part of the high intensity gamma-ray source (HIGS) upgrade, the booster synchrotron has been built and commissioned in 2006. It ramps the electron beam between 0.24 and 1.2 GeV for top-off injection into the Duke storage ring. The booster has vertical injection/extraction which uses symmetrical schemes with a bumped orbit. The injection/extraction kickers and corresponding septum magnets are located in the opposite straight sections of the booster ring separated by about 1/4 of the vertical betatron wave. Due to the non-ideal properties of the magnetic material, the magnetic field leaks out into the stored beam chamber, which results in orbit distortion, tune and chromaticity shifts, and change of coupling. The dynamics impacts due to the leaked septum fields have been successfully compensated to achieve good injection efficiency.
Keywords :
accelerator magnets; booster injectors; particle beam dynamics; particle beam extraction; particle beam injection; HIGS booster; beam dynamics effects; booster synchrotron; extraction Lambertson septum; high intensity gamma-ray source upgrade; injection/extraction kickers; septum magnets; top-off injection; Coils; Electron beams; Magnetic fields; Magnetic materials; Magnetic properties; Magnets; Optical coupling; Radio frequency; Storage rings; Synchrotrons;