Title : 
6 GHz time domain measurement of fast-transient events
         
        
        
            Author_Institution : 
Bell-Northern Research Ltd, P.0, Box 3511, Station C Ottawa, Ontario Canada, KIY 4H7
         
        
        
        
        
        
            Abstract : 
Very wideband (6 GHz) measurements of the discharge current produced by a commercially available electrostatic discharge (ESD) generator are presented. The results are compared to similar measurements obtained using the IEC 801-2 measurement method (1GHz bandwidth). Under contact discharge conditions, the wideband results indicate a risetime seven times faster than that reported using the IEC method and a peak current amplitude at least four times greater. EM1 generated by a contact discharge is shown to be a more severe threat to high speed telecommunications equipment than is the EM1 generated by an air discharge.
         
        
            Keywords : 
Bandwidth; Current measurement; Electrostatic discharge; Electrostatic measurements; IEC standards; Oscilloscopes; Resistors; Testing; Time measurement; Wideband;
         
        
        
        
            Conference_Titel : 
Electromagnetic Compatibility, 1992. Symposium Record., IEEE 1992 International Symposium on
         
        
            Conference_Location : 
Anaheim, CA
         
        
            Print_ISBN : 
0-7803-0713-5
         
        
        
            DOI : 
10.1109/ISEMC.1992.626143