  • Abstract
    In KEKB, synchrotron radiation interferometers (SRMs)[1] are used for measuring the transverse beam sizes. There is also a tool for enlarging the vertical beam size intentionally by making an asymmetric bump, called an "iSize" bump, at one of the strongest non-interleaved sextupole magnets in each KEKB ring. The calibrations of the SRMs were checked by comparing the measured vertical beam sizes with those calculated using the computer code "SAD". The obtained correction factors are 1.000plusmn0.045 for HER and 0.971plusmn0.060 for LER, which are consistent with the calibration factors of SRMs [2] within errors. Using the obtained calibration factor, the x-y coupling of each ring was calculated.
  • Keywords
    accelerator magnets; calibration; particle beam diagnostics; particle interferometry; storage rings; synchrotron radiation; high energy ring; iSize bump; low energy ring; sextupole magnets; synchrotron radiation interferometer calibration; transverse beam sizes; Calibration; Computer errors; Extraterrestrial measurements; Magnets; Optical coupling; Orbital calculations; Orbits; Size control; Size measurement; Synchrotron radiation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2007. PAC. IEEE
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0916-7
  • Type

    conf

  • DOI
    10.1109/PAC.2007.4440795
  • Filename
    4440795