Title :
Comparison between sparc e-meter measurements and simulations
Author :
Ronsivalle, C. ; Giannessi, L. ; Quattromini, M. ; Bacci, A. ; Rossi, A.R. ; Serafini, L. ; Boscolo, M. ; Chiadroni, E. ; Ferrario, M. ; Filippetto, D. ; Fusco, V. ; Gatti, G. ; Migliorati, M. ; Mostacci, A. ; Vaccarezza, C. ; Vicario, C. ; Cianchi, A. ;
Author_Institution :
ENEAC.R. Frascati, Frascati
Abstract :
For the SPARC photoinjector commissioning the emittance compensation process has been studied experimentally under different beam conditions (variation of charge, spot size, beam shape....) by a novel device called "emittance-meter", consisting in a movable emittance measurement system based on the ID pepper pot method scanning a region 1.2 m long downstream the RF-gun. The results of a detailed comparison between the measurements and beam dynamics simulations performed by the codes (PARMELA,HOMDYN,TREDI) employed for SPARC design are presented and discussed here.
Keywords :
particle beam diagnostics; particle beam dynamics; 1D pepper pot method; HOMDYN code; PARMELA code; SPARC emittance-meter measurements; SPARC photoinjector; TREDI code; beam dynamics simulations; emittance compensation process; Cathodes; Charge measurement; Current measurement; Energy measurement; Magnetic field measurement; Performance evaluation; Phase measurement; Position measurement; Shape measurement; Size measurement;
Conference_Titel :
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0916-7
DOI :
10.1109/PAC.2007.4440957